Full Address: Walnut Cottage, Wirksworth, Matlock DE4 4AH, UK
Site: Walnut Cottage
Description:
Just to confirm the objectives for the system check: Check if the current system meets current general binding rules Check the size of the current system to ensure it is adequate for the property Check if there is any surface water from the downpipes entering the system Check the condition of the tank for crack/leaks/structural condition If possible to check the outlet point, if this is to ground, we will check for any signs of leeching (indicates drainfield failure) Provide a full report with photographs and any quotes should remedial works or replacement be required Call Helen Davies when on site
Full Address: Walnut Cottage, Wirksworth, Matlock DE4 4AH, UK
Site: Walnut Cottage
Description:
Just to confirm the objectives for the system check: Check if the current system meets current general binding rules Check the size of the current system to ensure it is adequate for the property Check if there is any surface water from the downpipes entering the system Check the condition of the tank for crack/leaks/structural condition If possible to check the outlet point, if this is to ground, we will check for any signs of leeching (indicates drainfield failure) Provide a full report with photographs and any quotes should remedial works or replacement be required Call Helen Davies when on site
We will be away but if you could contact the Estate office 01367240786 (Mrs Lander) or estbuscot@aol.com Booked for 8am - Eurotech PO005010 1 x 2” VJ 1 x 2” plastic gate valve 1 x 2” straight connector 6 x 2” threaded to plain barrel nipple 4 x 2” union 4 x 2” 90 1 x 2” Tee 6 meters 2” pipe 2 x 3 meters 2 man 5 hrs Ladder Small tanker 1000 gal Please take just in case 2 x 2” VJ 2 x 2” straight connectors * some Flygt auto coupler have a built in 90 bend if this is the case the above will need to be used. Can you also make sure the engineer takes 2 x 2” stub flange 2 x 2” seals 2 x 2” backing rings 8 x bolts, washers and nut
Full Address: Masson Lees Farm, Salters Ln, Matlock DE4 2PA, UK
Site: Masson Lees Farm
Description:
Ring Emily with half hour notice 07890 590393 - NS - Service not sure of system - goes to soakaway may need repairs and a de-sludge following this visit - Quoted £192.50 + VAT
Booked for 8am to meet tanker - Eurotech Quote 2 man 1.30 with service visit 1 x new Tricel diffuser 1 x 3/4 male threaded to hose tail 90 Tanker with jetter
Call out Can you please arrange for someone to come out and have a look at our Sewage Treatment Plant as it doesnt seem to be turning and appears to be stuck! We had it emptied last Friday and the situation is still the same.
Passing visit following remedials - as the unit had been emptied for remedial work, unable to verify that it is treating correctly therefore, recommended a passing visit to verify treatment. As been emptied levels are low
Just to confirm the objectives for the system check: 1. Check if the current system meets current general binding rules 2. Check the size of the current system to ensure it is adequate for the property 3. Check if there is any surface water from the downpipes entering the system 4. Check the condition of the tank for crack/leaks/structural condition 5. If possible to check the outlet point, if this is to ground, we will check for any signs of leeching (indicates drainfield failure) 6. Provide a full report with photographs and any quotes should remedial works or replacement be required Call Kirsty whilst on site for de-brief to ensure she has all info to produce report
Full Address: Masson Lees Farm, Salters Ln, Matlock DE4 2PA, UK
Site: Masson Lees Farm
Description:
Ring Emily with half hour notice 07890 590393 - NS - Service not sure of system - goes to soakaway may need repairs and a de-sludge following this visit - Quoted £192.50 + VAT
Full Address: Holly Cl, Bowerchalke, Salisbury SP5 5BD, UK
Site: Bowerchalk
Equipment: Sprinkler unit gravity with Doc 3 recycling pump
Description:
Notes from AJC Below: Information from the engineers visit, from this morning 13 June 25 System at site is a Septic Tank , Aeration Unit, and outfall chamber. Arrived site, septic tank at its correct operating level, the aeration unit was making loud water noise, the discharge pipe from the pump in the aeration unit had disconnected from its spreader plate/ distribution head. So, although it is running all effluent has been running back down on top of the pump rather than over the media, noted a tide mark above the media. The outfall chamber was flooded to approx. 500mm above its outlet, with a tide mark in this chamber indicating it floods to approx. 800mm at times of peak flow. The pump discharge pipe was reconnected to the spreader plate above media and the media zone then flooded, suggesting media is so clogged it is virtually watertight and creating another chamber in effect. This has been caused by the outfall being blocked so there is no void between the bottom of the media zone for the effluent to drop out. The outfall was jetted to a distance of approx. 25m until the hose would travel no further, , continued to jet until water supply ran out, the back flow was the consistency of thick slurry. The tanker emptied the aeration unit and then topped up to the required volume of 1000g . this leaves a lot of thick heavy sludge / fat in the bottom of the septic tank . to remove this ,it will need jetting to liquify so it will run to tanker hose for removal. This is part due to the tank never being fully emptied ( 1000g for this site doesnt empty everything, you should allow 2000g each time ) and it goes on getting thicker and harder to remove as on this tank access inside tank is poor for this. Recommendation / remedy 1. To jet outfall chamber with tanker in attendance for as long as necessary for either thick slurry to stop running back or the end located. 2. The media should also be removed and cleaned, so effluent can run through freely A new soakaway may be required at this site.
Full Address: Oakes Wood House, Tedgness Road, Grindleford, Hope Valley S32 2HX, UK
Site: Oakes Wood House
Equipment: Maxi Twin 1600/6VX
Description:
PLEASE CALL 30 MINS BEFORE ARRIVAL - Notes from Nimesh on call - Called to report alarm sounding, after looking through ST, got customer to press reset on the panel and this turned off but he called back and it was back on, I have got him to turn the panel off to stop the alarm sounding and could do with a callout tomorrow