Full Address: Annandale, Aldersey Park, Aldersey Chester CH3 9ED
Site: Annandale
Equipment: Marsh Ensign 45 with 50mm pumped outlet and external compressor
Description:
Works are to investigate to see if it is a warranty or not and repair once we know - Please keep Rob and Sophie updated - If works will be chargeable due to wipes etc. do not complete works without authorization Manhole cover/frame fix 4 x edging stone 2 x post fix - Screwfix - 156GL 1 x Rapid set cement 2 x sand marsh unit: 2 x 3/4” x 750 diffusers 2 x 3/4” 1000mm diffuser We are getting 2 different size diffusers as we do not know what length is in there unless we ask marsh. All just in case 3 x 3/4” 90 1 x 3/4 tee 2 x 3/4 threaded to plain barrel nipple 1 x 3/4” 90 plain to threaded 2 x 3m pipe 5 meters 50mm duct- just in case 10meter 3/4” air hose- just in case Ladder Tank entry if you cannot get in with ladder. Tanker with media guard 1000 gal? - PO006467 Eurotech 2 man I would say possibly all day
Full Address: Annandale, Aldersey Park, Aldersey Chester CH3 9ED
Site: Annandale
Equipment: Marsh Ensign 45 with 50mm pumped outlet and external compressor
Description:
Works are to investigate to see if it is a warranty or not and repair once we know - Please keep Rob and Sophie updated - If works will be chargeable due to wipes etc. do not complete works without authorization Manhole cover/frame fix 4 x edging stone 2 x post fix - Screwfix - 156GL 1 x Rapid set cement 2 x sand marsh unit: 2 x 3/4” x 750 diffusers 2 x 3/4” 1000mm diffuser We are getting 2 different size diffusers as we do not know what length is in there unless we ask marsh. All just in case 3 x 3/4” 90 1 x 3/4 tee 2 x 3/4 threaded to plain barrel nipple 1 x 3/4” 90 plain to threaded 2 x 3m pipe 5 meters 50mm duct- just in case 10meter 3/4” air hose- just in case Ladder Tank entry if you cannot get in with ladder. Tanker with media guard 1000 gal? PO006467 Eurotech 2 man I would say possibly all day
Full Address: Crosslands Drive Chesterfield Derbyshire S43 3XZ
Site: Staveley Waterside (The Moorings)
Equipment: Foul Pump Station and Surface Water Pump Station
Description:
BOOKED FOR 12-2 - DCC - 1st service - Never attended site before, please take as many details as possible - please call Steph with 30mins notice 01246 826000
Full Address: The Plant Place, 169 Fleetwood Rd S, Thornton-Cleveleys FY5 5NS, UK
Site: The Plant Place
Equipment: Ultra Polylock 100 PE with twin pumped outlet
Description:
1 man 2 hours - SSC - November 2025 Service - With Universal Tankers PO: 006462 as having smell issues Please take jet wash incase tanker needs help washing down.
Full Address: Troutbeck, Windermere LA23 1PH - W3W – anguished.pipeline.shell
Site: Troutbeck
Description:
Troutbeck is removing the pumpstation and rerouting pipework at Troutbeck WWTW, Troutbeck, Ambleside, Cumbria, LA22 1PQ. W3W – anguished.pipeline.shell
Full Address: Armoury Ln, Prees, Whitchurch SY13 2EN, UK
Site: Fox Hollow
Description:
Site Contact Catherine the current owner but not our customer - 07918 603360 Just to confirm the objectives for the system check: 1. Check if the current system meets current general binding rules 2. Check the size of the current system to ensure it is adequate for the property 3. Check if there is any surface water from the downpipes entering the system 4.Dye test of all accessible downpipes/guttering at ground level 5. Check the condition of the tank for crack/leaks/structural condition 6. If possible to check the outlet point, if this is to ground, we will check for any signs of leeching (indicates drainfield failure) 7. Provide a full report with photographs and any quotes should remedial works or replacement be required Call Kirsty whilst on site for de-brief to ensure she has all info to produce report
Ring Rita on site with an hours notice - 07930 565060 Just to confirm the objectives for the system check: 1. Check if the current system meets current general binding rules 2. Check the size of the current system to ensure it is adequate for the property 3. Check if there is any surface water from the downpipes entering the system 4.Dye test of all accessible downpipes/guttering at ground level 5. Check the condition of the tank for crack/leaks/structural condition 6. If possible to check the outlet point, if this is to ground, we will check for any signs of leeching (indicates drainfield failure) 7. Provide a full report with photographs and any quotes should remedial works or replacement be required Call Kirsty whilst on site for de-brief to ensure she has all info to produce report
Full Address: Ironworks Farm, Street Ln, Ripley DE5 8HT, UK
Site: Ironworks Farm
Description:
spoken to Julie, she has a cesspit for the farm, They have a caravan site too where caravan users tip their waste - this doesn't sound right She can see that water is leaking She would like a visit so we can try and investigate to see where water is getting in, said we can dye test surface water etc and try to determine some answers
Full Address: Mount Pleasant Wigmore, Leominster HR6 9UG
Site: Mount Pleasant
Equipment: Marsh Ensign 10
Description:
Engineer to collect expanding foam and screws from builders merchants please - Booked for AM Reattend site and screw down the compressor housing to the frame and fill in the cavity under the housing with expanding foam to see it this helps alleviate the vibration issues. Please note that the engineer would need to cut a hole in the base of the compressor housing to be able to insert the expanding. Please take: screws, drill bit and expanding foam - You will need about an hour on site and will need to cut the expanding foam after it has set so it is not sticking out the hole which you have drilled
Full Address: The Mill House, 17 Mill Ln, Asfordby, Melton Mowbray LE14 3SF, UK
Site: 17 Mill Lane
Description:
Just to confirm the objectives for the system check: 1. Check if the current system meets current general binding rules 2. Check the size of the current system to ensure it is adequate for the property 3. Check if there is any surface water from the downpipes entering the system 4. Check the condition of the tank for crack/leaks/structural condition 5. If possible to check the outlet point, if this is to ground, we will check for any signs of leeching (indicates drainfield failure) 6. Provide a full report with photographs and any quotes should remedial works or replacement be required Call Kirsty whilst on site for de-brief to ensure she has all info to produce report