Price £13,995 + VAT Tank FujiClean CEN5 (7-person) sewage treatment plant with gravity outlet. Installer Shaun Coupe Section 50/106 Not applicable / not required for this project. EA Permit Not required. Discharge is less than 5m³/day to a watercourse; site checks confirm no SSSI or Ground Source Protection Zones nearby. Included Building Control: Included Electrician: Included Spoil Removal: Included Tank Empty Not included but they have requested – £265 NO VAT per 1,000 gallons if undertaken by MPC. Other Notes Property: Hobbergate Farm – 3-bedroom dwelling currently served by non-compliant septic tank discharging to lagoon. Discharge via gravity feed (~30m) to ditch within property boundary. Manhole lids specified as D400 to allow continued agricultural use (livestock and machinery). Power supply to be taken from house with dedicated fuse for system; included in works. Surface water confirmed separate and directed to front ditch. Site access good; livestock to be kept clear during works. Existing tank to be emptied, broken in, and backfilled with spoil.
Address Gorstycroft, Wood Lane, Mobberley, Knutsford, WA16 7NJ Tank / System Tricel UK12 (12 person) Sewage Treatment Plant with gravity outlet Installer Shaun Coupe Section 50/106 N/A EA Permit N/A Included Building Control - included Electrician - included Tanker - not included Spoil Removal - to be lost on site in the waste ground at the top of the back field Decommission - to be broken in and backfilled and stell plates to be lost in tank Other Notes We have noted that the excavation area has limited access. A shrub will need to be removed, as discussed with Rob, and the nearby tree will require some pruning to prevent any damage during the works. Tree roots should be taken into consideration; however, as the tree does not have a large canopy, this is unlikely to present a significant issue. Payment plan for final invoices to neighbour.
Price £16,844 + VAT Tank Marsh Ensign 12 (12-person) sewage treatment plant with pumped outlet and 1 m trimmable riser. Compressor: FujiMAC 100 upgrade included (quiet operation; Marsh-supplied compressor retained as spare). Installer Chris Britland Section 50/106 Not applicable / not required for this project. EA Permit Not required. Tank Empty Existing septic tank to remain in place (no decommission). Building Control / Electrician - Not included (client already appointed). Spoil Removal To be distributed on site Other Notes Property: main 6-bed house plus two 1-bed cabins (with sofa beds); 12-person design capacity. Access via field (right of way in deeds); good space for plant/materials; deliveries staggered. Trees under TPO: no removals; minor branch trimming may be needed. Surface water already separated from foul (compliant). Client to provide power; STP requires dedicated fused supply.
BOOKED FOR 10AM Return trip to complete compliance check meeting Chris from Beta - Please speak with Charlie before you attend and only knock on Lakeside Cottage. Do not contact any neighbors! Just to confirm the objectives for the system check: 1. Check if the current system meets current general binding rules 2. Check the size of the current system to ensure it is adequate for the property 3. Check if there is any surface water from the downpipes entering the system 4. Check the condition of the tank for crack/leaks/structural condition 5. If possible to check the outlet point, if this is to ground, we will check for any signs of leeching (indicates drainfield failure) 6. Provide a full report with photographs and any quotes should remedial works or replacement be required Call Kirsty whilst on site for de-brief to ensure she has all info to produce report
Fuji sample - Influent and effluent Please take checklist and complete one on each visit - Photo of this must be submitted on each visit Take sample and influent and effluent to be brought back to the Office for testing Please complete the checklist within the kiosk on each visit. A photo of the completed check list must be sent through after each sample visit
Rowleth End, Low Row, Richmond DL11 6PY - ///survived.chatting.tailwind Tank Marsh Ensign 12 (12-person) sewage treatment plant with pumped outlet and 1 m trimmable riser. Compressor: FujiMAC 100 upgrade included (quiet operation; Marsh-supplied compressor retained as spare). Installer Chris Britland Section 50/106 Not applicable / not required for this project. EA Permit Not required. Tank Empty Existing septic tank to remain in place (no decommission). Building Control / Electrician - Not included (client already appointed). Spoil Removal To be distributed on site Other Notes Property: main 6-bed house plus two 1-bed cabins (with sofa beds); 12-person design capacity. Access via field (right of way in deeds); good space for plant/materials; deliveries staggered. Trees under TPO: no removals; minor branch trimming may be needed. Surface water already separated from foul (compliant). Client to provide power; STP requires dedicated fused supply.
TAKE 110MM RAT FLAP (ON REMEDIAL SHELF) Hobbergate Farm, Oulton Heath, Stone, ST15 8TN Tank FujiClean CEN5 (7-person) sewage treatment plant with gravity outlet. Installer Shaun Coupe Section 50/106 Not applicable / not required for this project. EA Permit Not required. Discharge is less than 5m³/day to a watercourse; site checks confirm no SSSI or Ground Source Protection Zones nearby. Included Building Control: Included Electrician: Included Spoil Removal: Included Tank Empty Not included but they have requested – £265 NO VAT per 1,000 gallons if undertaken by MPC. Other Notes Property: Hobbergate Farm – 3-bedroom dwelling currently served by non-compliant septic tank discharging to lagoon. Discharge via gravity feed (~30m) to ditch within property boundary. Manhole lids specified as D400 to allow continued agricultural use (livestock and machinery). Power supply to be taken from house with dedicated fuse for system; included in works. Surface water confirmed separate and directed to front ditch. Site access good; livestock to be kept clear during works. Existing tank to be emptied, broken in, and backfilled with spoil.
Just to confirm the objectives for the system check: 1. Check if the current system meets current general binding rules 2. Check the size of the current system to ensure it is adequate for the property 3. Check if there is any surface water from the downpipes entering the system 4. Check the condition of the tank for crack/leaks/structural condition 5. If possible to check the outlet point, if this is to ground, we will check for any signs of leeching (indicates drainfield failure) 6. Provide a full report with photographs and any quotes should remedial works or replacement be required Call Kirsty whilst on site for de-brief to ensure she has all info to produce report
Meeting ET on site at 8am PO 007098 1No New KSB Amarex N S50-172/012 YLG-160 - KSB PO006356 Tanker to remove up to 1000 gallons 2No Waste water Engineers on site for up to 1 hour While on site please have a look at - The current drainage is vented via a manhole. The waste passing through this system requires a sealed manhole with a vent pipe, so this also needs urgent rectification